Order# VGC501-MPG500-CF275
MPG500-CF275 & VGC501 Cold Cathode & Pirani Gauge System
MPG500 Pirani and Cold Cathode (Inverted Magnetron) Combination High Vacuum Full Range Gauge System Includes:
• MPG500 with 2.75" OD Conflat Port (Rotatable)
• VGC501 Vacuum Gauge Controller (398-481)
• 15' Cable
2 NIST Traceable, A2LA Calibration Certificates
MPG500 Cold Cathode and Pirani Vacuum Gauge (Transmitter)
• Part Number: MPG500-CF275 (3MB0-008-000P)
• 2.75" OD Conflat Flange Port (Rotatable)
• Cold Cathode (Inverted Magnetron) & Pirani
• MPG500 Series Gemini Combination Gauge
• Rugged and dependable
• One logarithmic analog output signal: 0…. +10.5 V
High Vacuum Gauge System, Measures From:
• 1x10-9 mbar to Atmosphere
• 7.6x10-10 Torr to Atmosphere
VGC501 Vacuum Gauge Controller:
• Single Gauge Controller, 100... 240 V~
• (1) Measurement Channel
VGC501 Measurement Unit (selectable):
mbar, Micron, Torr, Pa, hPa or Voltage
USB interfaces (front and rear) along with an additional Ethernet interface provide added data logging capabilities, while the 16 bit A/D converter produces excellent process measurement resolution. A dot matrix menu simplifies changes to the parameter, sensor, and general settings. The bright, easy to read display provides a bar graph for at-a- glance pressure vs. time data.
|
|
MPG500 Series
Specifications
|
|
|
Measurement range (air, N2)
|
1
x 10-9 … 1000 mbar
|
|
7.6
x 10-10 … 760 Torr
|
|
Accuracy (N2)
|
|
|
1
x 10-8 … 1 x 10-2 mbar
|
±30%
of reading
|
|
1
x 10-2 … 100 mbar
|
±30%
of reading
|
|
100
… 1000 mbar
|
±50%
of reading
|
|
Repeatability (N2)
|
±5%
of reading
|
|
1
x 10-8 … 100 mbar
|
|
Mounting
Orientation
|
ANY
|
|
Admissible pressure bar (absolute)
|
10
bar (limited to inert gases <55°C)
|
|
Admissible temperature
|
|
|
Operation (ambient)
|
+5
… +55°C
|
|
Storage
|
-40
… +70°C
|
|
Bake-out at Flange*
|
150°C
|
|
Filament temperature
(Pirani)
|
120°C
|
|
Supply Voltage
|
|
|
At Gauge
|
+14.5
… +30 VDC
|
|
Ripple
|
<1 V (pp)
|
|
Power
Consumption
|
<3 W
|
|
Fuse
to be connected
|
<1 AT
|
|
Output Signal
(Measurement Signal)
|
|
|
Voltage Range (analog
output)
|
0
… +10.5 V
|
|
Measurement Range
|
+1.398
… +8.598 V
|
|
Voltage vs. Pressure
|
logarithmic, 0.6 volts per decade
|
|
Response Time (pressure
dependent)
|
|
|
> 10-6 mbar
|
<100
ms
|
|
1 x 10-6 … 1 x 10-8 mbar
|
1
s
|
|
Identification gauge
|
85 kΩ
|
|
Status Signal (digital
output) FCC Connector
|
|
Current rating
|
100
mA
|
|
High voltage is ON
|
+14.5
… +30V (dc) depending on supply voltage
|
|
High Voltage is OFF
|
0
V (dc)
|
|
Electrical
Connection
|
FCC 68 appliance connector,
|
|
|
8 poles, female
|
|
Sensor
Cable
|
8 poles plus shielding
|
|
High
voltage (in the measuring chamber)
|
|
Ignition voltage
|
<4.5 kV
|
|
Operating Voltage
|
<3.3 kV
|
|
Current
in measuring chamber
|
|
High Current
|
<380 μA
|
|
Low Current
|
<130 μA
|
|
Materials exposed to vacuum
|
stainless
steel, Al2O3, Glass, Ti
|
|
|
Mo,
Ni alloy, W
|
|
*Without electronics
|
|
**The minimum voltage of the supply unit must be increased proportionally
to the length of the sensor cable.
|
Contact LDS Vacuum with any questions:
Phone (407)862-4643 via Fax (407)862-8723 or
info@ldsvacuum.com
This item is no longer available to customers with a FINAL DESTINATION OUTSIDE THE US, Mexico or Canada.
Contact Manufacturer To Purchase Directly.
LDS Vacuum Products is a 100% woman owned company and certified Woman Owned Small Business (WOSB) The logos and/or trademarks appearing on this page are not owned by or registered to LDS but, rather, designate products sold by LDS, and are owned and/or registered to the manufacturers or suppliers of the products. |
|